Beyond Euglycemia: Case Studies Using Continuous Glucose Monitoring in Elite Athletes Without Diabetes During Record Athletic Events
Abstract
Glucose data regarding extreme elite performances in athletes without diabetes remains limited. The purpose is to characterize continuous glucose monitoring (CGM) responses in elite athletes across distinct high-performance contexts. This descriptive case series includes three separate elite athletes who used a CGM during their respective sporting events. The first is an ultra-endurance relay cycling world-record performance (Race Across the West, RAW), the second is a continuous high-intensity Everesting Challenge cycling record attempt, and the third is a maximal constant-weight no-fins breath-hold depth dive performed in international competition. Glycemic outcomes, as measured by CGM, included mean, maximum, and minimum glucose, glucose standard deviation (SD), and the percentage of time in tight glucose range (TITR: 70-140 mg/dL; 3.9-7.8 mmol/L), time below range (TBR: 140 mg/dL; >7.8 mmol/L). Other performance data, including peak power, heart rate, and lactate, are also provided where available. During the RAW challenge lasting 44 h and 20 min, mean glucose was 91 ± 23.2 mg/dL (mean ± SD) with 9.15% TBR and 35.58% TITR during cycling and 115 ± 24.7 mg/dL with 9.11% TBR and 43.16% TITR during resting periods. In contrast, the Everesting Challenge cycling record attempt demonstrated a persistently elevated glucose profile (160 ± 5.7 mg/dL), minimal variability (CV 3.5%), and 100% TAR140. Following the maximal breath-hold depth dive, interstitial glucose was 100% TAR140…
How strong is the evidence?
Evidence Hub reads this as a case series, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.