Application of polyaniline/zinc oxide nanocomposites for non-enzymatic cholesterol detection: A preliminary investigation on the effect of dopants on the morphology, thermal stability, electrochemical and sensing behavior of the nanocomposites
Abstract
ABSTRACT Cholesterol is a major cause for cardiovascular diseases; and therefore, timely detection of cholesterol is of paramount importance to prevent such diseases. Herein, a non-enzymatic sensor for the detection of cholesterol has been fabricated using polyaniline (PANI) and its nanocomposites (NCs) with ZnO nanoparticles (NPs). For this purpose, a series of NCs has been synthesized by varying the loading of the ZnO NPs as 2%, 3%, 5% and 8% with respect to the weight percentage of the aniline monomer. In addition, two different doping agents, namely camphor sulfonic acid (CSA) and hydrochloric acid, have been used to prepare PANI and its NCs. Electrochemical studies have revealed that as the amount of ZnO NPs increased, the capacitive behavior of the composite also increased. Similar trend was observed in case of HCl-doped polyaniline NCs. PANI/ZnO 8% NCs for both HCl and CSA dopant indicated good capacitive behavior for sensing cholesterol. The best electrode was further tested for sensitivity, and was found to exhibit a value of 0.38 mA mM−1 cm−2. The limit of detection of the prepared sensor was found to be 0.30 mM concentration in PBS buffer under the linearity range of 0.75 mM to 1.5 mM (adj. R2 = 0.97). Highlights Polyaniline/ZnO nanocomposites (2%, 3%, 5%, and 8%) with two different doping agents (CSA and HCl) were synthesized and compared. Physical, optical, and electrochemical properties of the nanocomposites resulted in favor of 8% ZnO loadings. Cholesterol…
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.