Case Report: Calcium sensing receptor gene gain of function mutations: a case series and report of 2 novel mutations
Abstract
Autosomal dominant hypocalcemia (ADH1) is a genetic disorder characterized by low serum calcium and low or inappropriately normal levels of parathyroid hormone. The disease is caused by a heterozygous activating mutation of the calcium-sensing receptor (CaSR) gene, encoding a G-Protein-coupled cell membrane sensor of extracellular calcium concentration mainly expressed by parathyroid glands, renal tubules, and the brain. ADH1 has been linked to 113 unique germline mutations, of which nearly 96% are missense mutations. There is often a lack of a clear genotype/phenotype correlation in the reported literature. Here, we described a case series of 6 unrelated ADH1 probands, each one bearing a gain-of-function CaSR mutation, and two children of one of these cases, matching our identified mutations to the same ones previously reported in the literature, and comparing the clinical and biochemical characteristics, as well as the complication profile. As a result of these genetic and clinical comparisons, we propose that a genotype/phenotype correlation may exist because our cases showed similar presentation, characteristics, and severity, with respect to published cases with the same or similar mutations. We also contend that the severity of the presentation is highly influenced by the specific CaSR variant. These findings, however, require further evaluation and assessment with a systematic review.
How strong is the evidence?
Evidence Hub reads this as a case report, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.