Evaluation of right ventricular pacing-induced coronary microvascular dysfunction using guide wire-based sensor technology: a case report
Abstract
Abstract Background The diagnosis of ischaemic non-obstructive coronary artery disease is crucial for the differential diagnosis of chest pain. However, the pathophysiology of chest pain and evaluation of coronary microcirculation in patients with right ventricular pacing (RVP) have not been sufficiently reported. Case summary The patient was a 53-year-old woman who underwent dual-chamber pacemaker implantation because of sinus node dysfunction. She experienced chest pain before pacemaker implantation; however, the frequency and severity of her chest pain increased after the implantation. She was referred for the evaluation of coronary microvascular dysfunction (CMD). Coronary angiography revealed no significant stenosis of the epicardial vessels. Subsequent evaluation of CMD showed that while the index of microcirculatory resistance [normalized index of microcirculatory resistance (IMR)] in the left anterior descending artery (LAD) was 19 U during the native rhythm, an increase in IMR (normalized IMR: 27 U) was observed during RVP. Discussion Right ventricular pacing may not only induce left ventricular dyssynchrony due to non-physiological excitation propagation but may also provoke CMD in the LAD territory, particularly in the septal branches, which could contribute to pacing-induced structural CMD and chest pain. However, RVP may well be a contributing but not exclusively a factor of CMD.
How strong is the evidence?
Evidence Hub reads this as a case report, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.