Highly sensitive detection of carbendazim in juices based on mung bean-derived porous carbon@chitosan composite modified electrochemical sensor
Abstract
We reported a simple and scalable strategy for the preparation of mung bean-derived porous carbon@chitosan (MBC@CTS) composite, which was used to optimize the glassy carbon electrode (GCE). The MBC@CTS/GCE sensor was applied for the carbendazim (CBZ) detection. For the MBC@CTS composite, MBC with three-dimensional hierarchical structure presented large specific surface area, good adsorbability, and high electrical conductivity, while CTS had good film-forming property, hydrophilicity performance, and adhesion capacity. The MBC@CTS/GCE sensor exhibited wonderful electrochemical detection performance towards CBZ. Under the optimized conditions, the MBC@CTS/GCE sensor showed a linear concentration range from 0.1 to 20 μM with relatively low limit of detection (LOD) of 20 nM. In addition, the fabricated sensor with good reproducibility, stability, and selectivity were successfully applied for the CBZ detection in apple and tomato juices with low relative standard deviation of 2.4 %-4.2% and satisfactory recoveries of 98.8-103.2%.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.