Electroactive polypyrrole-molybdenum disulfide nanocomposite for ultrasensitive detection of berberine in rat plasma
Abstract
Electroactive polypyrrole-molybdenum disulfide (MoP) nanocomposites were synthesized and used for modifying screen-printed carbon electrodes (SPCEs) for ultrasensitive detection of berberine, an anticancer drug, in rat plasma. The electroactive nanocomposites were fabricated by exfoliating MoS2 followed by pyrrole polymerization. The effect of polypyrrole in the MoP nanocomposite was evaluated by varying the pyrrole concentration during polymerization, and the resulting nanocomposites prepared with pyrrole concentrations of 10, 20, 30 μL were named as MoP-1, MoP-2, and MoP-3, respectively. The electrochemical characterization of the three MoP nanocomposite sensors revealed that MoP-2/SPCE exhibited the highest electroactivity. The detection of berberine by the three MoP-coated SPCEs revealed that MoP-2/SPCE exhibited the highest activity against berberine due to a two-electron transfer mechanism on the MoP-2/SPCE electrode surface. The detection limit of berberine using the MoP-2/SPCE sensor was found to be about 0.05 μM, which is remarkably lower than the reported detection limits. The interference study proved the selectivity of the MoP-2/SPCE sensor toward berberine in the presence of other bioactive molecules and metal ions. The designed MoP-2/SPCE sensor retained 92% of its initial activity after 15 days of storage at room temperature, with RSD values of about 2.95% and 3.68% for the repeatability and reproducibility studies. Finally, the detection limit of berberine in…
How strong is the evidence?
Evidence Hub reads this as a experimental / empirical study, done in animal, not in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.