Computational approach and electrochemical measurements for protein detection with MIP-based sensor
Abstract
Rapid and accurate detection of proteins in biological fluids is increasingly required in the biomedical environment. Actually, it is performed with conventional techniques, which are generally run by robotized platforms at centralized laboratories. In this work, molecular dynamics calculations and an experimental procedure were conducted to set up electrochemical sensors based on polypyrrol (PPy) molecular imprinted polymers (MIP) for proteins detection. Here, prostate-specific antigen (PSA) was selected as a template model. Computational calculations indicate that for any PPy conformation and any amino-acid location in the protein, PSA molecules remain strongly inserted in the PPy polymer without biological alterations. One from possible orientations, appeared to be most probable as it presents the lowest absorption energy (-363 kcal mol-1) and largest contact area (4034.1 Å2). The device was then elaborated by in situ electropolymerization of PPy films. MIP's thickness and extraction duration were optimized by chronoamperometry. Square wave voltammetry technique was investigated for PSA detection in standard solution in the concentration range of 3x10 -8 ng.ml-1- 300 ng ml-1. According to the Hill equation, the equilibrium dissociation constant Kdbetween PSA and its imprint was estimated at Kd = (1.02 ± 0.54) × 10-14 M, confirming the strong binding between the designed MIP and the protein as predicted by the computational study. PSA concentration values directly measured…
How strong is the evidence?
Evidence Hub reads this as a simulation / modelling, done in computer models (in silico), not in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.