Abstract
A robust amperometric sensor was developed for the lactate detection in the extracellular matrix of cancer cells. The sensor was fabricated by separately immobilizing nicotinamide adenine dinucleotide (NAD+) onto a carboxylic acid group and lactate dehydrogenase (LDH) onto an amine group of bi-functionalized conducting polymer (poly 3-(((2,2':5',2″-terthiophen)-3'-yl)-5-aminobenzoic acid (pTTABA)) composited with N, S-doped porous carbon. Morphological features of the composite layer and sensor performance were investigated using FE-SEM, XPS, and electrochemical methods. The experimental parameters were optimized to get the best results. The calibration plot showed a linear dynamic range between 0.5 μM and 4.0 mM with the detection limit of 112 ± 0.02 nM. The proposed sensor was applied to detect lactate in a non-cancerous (Vero) and two cancer (MCF-7 and HeLa) cell lines. Among these cell lines, MCF-7 was mostly affected by the administration of lactate transport inhibitor, α-cyano-4-hydroxycinnamate (αCHC), followed by HeLa and Vero, respectively. Furthermore, the effect of αCHC concentration and treatment time on the lactate level in the cell lines were demonstrated. Finally, cytotoxicity studies were also performed to evaluate the effect of αCHC on cell viability.
How strong is the evidence?
Evidence Hub reads this as a experimental / empirical study, done in cell cultures (in vitro), not in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target